  1. Sea breeze mini split install#
  2. Sea breeze mini split code#
  3. Sea breeze mini split professional#

Bend the refrigeration lines carefully to the position needed to align with the drilled piping hole. INDOOR UNIT INSTALLATION (Cont) PREPARE REFRIGERATION LINES Refrigeration lines and wiring can be routed from the indoor unit several different ways using the cut-out access pieces on the back of the unit. If the cable is not of sufficient length, it will be necessary to purchase cable for this purpose. INDOOR UNIT INSTALLATION (Cont) MODEL INTERCONNECTING WIRE GAUGE 12H43ZGX 18H43ZGX 16 AWG 16 AWG -Table 1- POWER SUPPLY WIRE GAUGE 14 AWG 14 AWG CIRCUIT BREAKER 15 AMP 20 AMP Terminal board diagram covering plate MODEL 12H43ZGX 18H43ZGX terminal board power cable connection groove cable NOTE: Power connection cable is provided in the installation kit (sold separately). Fasten the rear panel to the wall at the location marked using the screws supplied with the unit. Once leveled, mark the screw locations on the wall.

sea breeze mini split

Hold the rear panel on the wall where you want the unit to be located and ensure that it is level using a plumb line or level.

Sea breeze mini split install#

INDOOR UNIT INSTALLATION INSTALL THE REAR PANEL-MOUNTING PLATE Always mount rear panel horizontally.

Sea breeze mini split code#

System grounding to be completed by a licensed technician, using National Electrical Code procedures and UL materials. Do not pull the power cable with excessive force. Applicable voltage range: the normal operation range of voltage is 90%~110% of rated voltage. The power supply wire gauge is specified in page 9. SELECT INSTALLATION LOCATION (Cont) ELECTRICAL SAFETY REQUIREMENTS The power supply must be of rated voltage via special circuit for air-conditioner. from radio equipment, medical equipment, etc.) INDOOR UNIT LOCATION Intake and outlet should not be obstructed. Locations exposed to: Machine oil Flammable or corrosive gasses High frequency waves (i.e. BASIC REQUIREMENTS FOR INSTALLATION POSITION Installation of Either unit in the following locations may cause malfunction.

Sea breeze mini split professional#

SELECT INSTALLATION LOCATION CAUTION : The air conditioning unit must be installed by professional technicians. z Do not install indoor unit in damp or wet locations. Disconnect all electric power supplies before servicing or installation z Do not use excessive torque on flare nuts during connection of the refrigeration tubes, or service valve on discharge line may be damaged. z Risk of electric shock can cause injury or death. SAFETY WARNINGS z Use Copper Wires only for Power Supply. MODEL NUMBERS Heat Pump SYSTEM MODEL Indoor Unit 12H43ZIGX 12H43ZGX Outdoor Unit 12H43ZOGX 12,000 BTU 208-230 VAC 13 SEER SYSTEM MODEL Indoor Unit 18H43ZIGX 18H43ZGX Outdoor Unit 18H43ZOGX 18,000 BTU 208-230 VAC 13 SEER 2 INSTALLATION INSTRUCTIONS MINI-SPLIT HEAT PUMP FOR MODELS: 12H43ZGX 18H43ZGX 950-0032-REV-E 12-14-06












Sea breeze mini split